Página 1 - Packet Reference Manual

©2001 Paxar Corporation. All Rights Reserved.TCMPCL2PR Rev. BA 06/00 Packet Reference ManualII CONTROL LANGUAGE MONARCH PRI

Página 2

Overview of Printer Differences ––––––––––––––––––––––––––––––While all four of these printers are very similar, somedifferences in operation and avai

Página 3 - Table of Contents

For example, you can use "" or ~034 to print the " character inyour batch data. Use ~~ to print the ~ character in your batchdata; oth

Página 4

Example {Format}{Batch Packet}Batch MethodThis is similar to the sequential method, but it is used whenyou want to send multiple batches. All data fo

Página 5 - Tabl e of Content s

3. Repeat step 2 for each field except the last one.4. For the last field, input data and send a batch header withthe quantity of labels you want prin

Página 6

Chapter 7. Status PollingThis chapter explains how to use status polling.There are two types of Status Polling:✦Inquiry Request--information about the

Página 7

Example:E ABThe status codes (A and B in this case) are ASCII equivalentsto the hexadecimal bits that represent the various types ofstatus responses.

Página 8

ENQ Reference Table - Byte #2Char Const.OFFConst.ONComp.FailureCorr.ErrorOnlineDataErrorBusy Active OnlineBit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bi

Página 9 - Chapter 1. Getting Started

ENQ Reference Table - Byte #2 (continued)Char Const.OFFConst.ONComp.FailureCorr.ErrorOnlineDataErrorBusy Active OnlineBit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bi

Página 10

ENQ Reference Table - Byte #3Char Const.OFFConst. ONLowBatteryFormatErrorWaitingtoDispenseLabelRibbonFaultStockFaultOnlineErrorBit 7 Bit 6 Bit 5 Bit 4

Página 11 - Chapter 1. Getting Started

ENQ Reference Table - Byte #3 (continued)Char Const.OFFConst. ONLowBatteryFormatErrorWaitingtoDispenseLabelRibbonFaultStockFaultOnlineErrorBit 7 Bit 6

Página 12

Job Request ––––––––––––––––––––––––––––––––––––––––––––––––A Job Request returns status information about the mostrecently processed print job. You

Página 13

Before You Begin ––––––––––––––––––––––––––––––––––––––––––––1.Connect the printer to the host. Refer to your printer’sdocumentation for more informa

Página 14

Job ResponseThe Job Response varies, depending on the type of requestsent to the printer. The following syntax is the response for aJob 0, 1,or 2 req

Página 15 - Chapter 2. Designing a Format

The following syntax is the response for a Job 3 request.Syntax {J,"Status1 A,B","Status2A,B,C,D,E","FMT-1","BCH-2&

Página 16

Status2C- Field Numberrepresents the field number within eachpacket. The packet header is the firstfield and each subsequent field isindicated by the

Página 17 - Printer Top Bottom Left Right

The following syntax is the response for a Job 4 request.Syntax {J,printed,total,"FMT-1","BCH-2"}printed the number of tags or lab

Página 18 - (Inches)

Job Status 0, 1, 2 Response Table (Status 1 Codes)Number Meaning0No error1Stacker fault2Supply problem4Hot printhead5Printhead open6Insufficient memor

Página 19

Job Status 0, 1, 2 Response Table (continued)Number Meaning51Invalid command52Invalid separator value53Graphic not found54Format for batch not found55

Página 20

MPCLII Packet Reference Manual7-14

Página 21

Chapter 8. DiagnosticsThis chapter explains how to ✦print a test label✦reset the printer✦call Technical Support.Before you call Service, print a test

Página 22 - Using Autobaud

nYou can also use an immediate command to print a test label,see Chapter 3, "Configuring the Printer," for more information.Using a 9446 or

Página 23 - Standard Syntax Guidelines

✦ENQ trailer characters✦RS232 trailer characters (these are the trailers for allcommunications, except an ENQ.)nThe ENQ/IMD, MPCL, and RS232 trailer c

Página 24

3.Type the following bar code field: B,1,12,F,110,115,1,2,120,5,L,0 p 4.Type the following text field: T,2,18,V,30,30,1,1,1,1,B,C,0,0,0 p }You have cr

Página 25 - Configuration Packet Header

4. The data stream prints out automatically when there isenough data to fill one label. Press the trigger to print anyremaining data on another label

Página 26

If the PC and Printer Aren’t CommunicatingIf your PC is having trouble communicating with your printer,follow these steps:✦Check any messages that occ

Página 27

nWhen you turn off the printer, wait two seconds before turningit back on.Calling Technical SupportTechnical support representatives are available Mon

Página 28

Chapter 9. ErrorsThis chapter provides explanations of your printer’s errors.The errors are classified by type and are listed in order from001 to 765,

Página 29

ErrorCodeDescription004 Supply length is invalid. See "Defining the FormatHeader" in Chapter 4 for valid lengths.005 Supply width is invali

Página 30

ErrorCodeDescription018 Code page selection must be 0 (Internal), 1 (ANSI),2 (DOS 437), or 3 (DOS 850).020 Vertical magnification must be 1 to 7 or 4

Página 31

ErrorCodeDescription031 Human readable option must be0 not UPCA or EAN1 no CD or NS5 NS at bottom, no CD6 CD at bottom, no NS7 CD and NS at bottom8 no

Página 32

ErrorCodeDescription102 Print quantity is outside the range 1 to 32000.104 Batch mode must be N (new) or U (update). See"Defining the Batch Head

Página 33 - Resetting Control Characters

ErrorCodeDescription210 Security value for a PDF417 bar code must be 0 to8. Correct the value and resend the format to theprinter.211 Narrow element

Página 34

ErrorCodeDescription222 Data type restriction is outside the range of 1 to 6.223 Option is not valid for the field.224 Bar code Inter-Character Gap mu

Página 35

10.Type COPY SAMPLE.FMT COM1. The following 2 inch by2 inch label prints:{F,25,A,R,M,508,508,"Fmt 25" p C,250,80,0,1,2,1,W,C,0,0,"MONA

Página 36

ErrorCodeDescription257 Feed mode must be 0 (continuous), 1 (on-demand),or 2 (rewind). (1 is the only valid option for the 1460printer.) See "D

Página 37 - Checking Current Buffer Sizes

ErrorCodeDescription267 Baud rate selection must be 0 (1200), 1 (2400), 2(4800), 3 (9600) or 4 (19200). Resend thecommunication settings packet.268 W

Página 38

ErrorCodeDescription285 The storage device type must be N (non-volatileRAM) or R (volatile RAM). See "Defining theMemory Configuration Packet&qu

Página 39 - Linecount

ErrorCodeDescription/Action380 Job request is outside the range 0 to 4.400 The character immediately following { is invalid.401 Internal software fail

Página 40 - Buffer Worksheet

Communication Failures–––––––––––––––––––––––––––––––––––––Errors 410 to 413 are usually caused by a hardware failure, byan incorrect SETUP option or

Página 41

ErrorCodeDescription412 There is a problem with flow control between theprinter and the host. Make sure the printer and thehost flow control settings

Página 42 - Optional RAM Buffer Sizes

ErrorCodeDescription424 Item in use. Record the error, then press the feedbutton and try to continue. If the error reappears,call Technical Support.

Página 43 - Sending Immedia te Comma nds

ErrorCodeDescription435 Internal software error caused by a downloaded taskthat already exists. Turn off the printer. Wait twoseconds and turn it ba

Página 44

ErrorCodeDescription575 The graphic included in your format could not befound.600 Imaging error because the batch was refused.Resend the batch. If th

Página 45

619 The JIS (16-bit) code for Kanji is invalid.Machine Faults –––––––––––––––––––––––––––––––––––––––––––––Errors 700 to 765 occur when there is a pro

Página 46

MPCLII Packet Reference Manual1-6

Página 47

ErrorCodeDescription705Invalid batch received. Press the trigger or E toclear the error. Check the batch data. Resend thebatch. If the error persi

Página 48

ErrorCodeDescription757 Load Supplies. The calibrated supply length differsby plus or minus .25 inches from the format. Press R to display the forma

Página 49

ErrorCodeDescription770 The print motor is not ready. Call Technical Support.771 The format specified by the application was notfound. Reload your a

Página 50 - For the 9494 printer

ErrorCodeDescription905 Illegal interrupt.906 Non-maskable interrupt.907 Low RAM error.908 Non Volatile RAM checksum failure.909 RAM corrupted.910 War

Página 51 - For the 9446 printer

ErrorCodeDescription937 Invalid ASCII hex data in record. The file youdownloaded is invalid. Verify the file’s integrity andreflash the printer.938

Página 52 - For the 1460 printer

nThese error messages will only appear on the printers with anLCD display (9446 and 1460).PrinterDisplayDescriptionWARNINGRAM Test FailureRAM check fa

Página 53 - Chapter 4. Defining Fields

PrinterDisplayDescriptionPOWER DOWNNVRAM Sum FailRAM checksum test failed. All formats,batches, graphics, and SETUP dataare lost. Reset your SETUP o

Página 54

Chapter 10. Printer OptimizationThis chapter provides information on how to improve yourprinter’s performance by ✦adjusting the print quality✦reducing

Página 55 - Chapter 4. Defining Fields

✦Select the print speed based on desired throughputand print quality. If print quality is more important,reduce the print speed, because a lower prin

Página 56

Reducing Imaging Time ––––––––––––––––––––––––––––––––––––––Imaging time is the time it takes the printer to image the datafor the first label after t

Página 57

Chapter 2. Designing a FormatThis chapter describes how to ✦determine what kind of information to use in yourformat.✦use the Supply Layout Grid and Fo

Página 58

2. Input data for each field, and send it with a batch headerusing the parameter U (update) and a quantity of zero.When the printer receives the data,

Página 59

General Format Tips and Hints ––––––––––––––––––––––––––––––– The following tips and hints are helpful to keep in mind whendesigning MPCLII formats.Wi

Página 60 - ) length field

With Bar Codes✦Be careful when rotating or placing a UPC/EAN barcode with human readable characters, because thebottom reference point is at the botto

Página 61

To use the optional entry method on a format packet:1. Create the format.2. Group the fields with the same parameters.3. Send the format packet to the

Página 62

MPCLII Packet Reference Manual10-8

Página 63

Appendix A. SamplesThis appendix contains sample formats and labels. You cancustomize any of these formats and labels to meet your needs.Sample UPCA

Página 64

Sample MaxiCode Packets –––––––––––––––––––––––––––––––––––MaxiCode is a two-dimensional bar code developed by UPS(United Parcel Service, Inc.). Data

Página 65

If you receive an error 612, check your MaxiCode data. Youmay have not correctly structured or left out one of the threerequired fields (postal code,

Página 66

Mode 2 Sample{F,1,A,R,E,400,400,"MAXI_M2" p B,1,99,V,040,140,33,7,0,8,L,0 p }MaxiCode bar-code (33){B,1,N,1 p 1,"[)>~030" p Me

Página 67

Mode 3 Sample{F,1,A,R,E,400,400,"MAXI_M3" p B,1,99,V,040,140,33,7,0,8,L,0 p } MaxiCode bar-code (33){B,1,N,1 p 1,"[)>~030" p M

Página 68

At this point, you are ready to send your design to the printer.To do this:7. Create a format packet, based on how you filled out yourworksheet. See

Página 69

Sample Compliance Packet–––––––––––––––––––––––––––––––––––{F,1,A,R,E,600,400,"RDCI" p L,V,500,115,90,85,3 p L,V,298,245,90,102,3 p L,V,500,

Página 70

Sample Batch Packet{B,1,N,1 p 1,"1234567890" p 2,"0987654321" p 3,"~42032678" p 4,"10028028662854" p 5,"1

Página 71 - Line Types

MPCLII Packet Reference ManualA-8

Página 72

Sample Zero Batch Packet –––––––––––––––––––––––––––––––––––{I,E,"~123~044~039~124~125~126" p }{F,5,A,R,G,576,768,"1HDREC1" p L,S

Página 73

Sample Batch Packet{B,5,N,0 p }{B,5,U,1 p 1,"6005710" p 2,"106" p 3,"3" p 4,"3" p 5,"ALLIED FREIGHT1234&q

Página 74 - "pattern" p

Sample Fixed Character Format Packet ––––––––––––––––––––––––{F,1,A,R,E,300,200,"TEXTILES" p T,1,10,V,250,50,0,1,1,1,B,C,0,0,0 p B,2,12,V,1

Página 75

MPCLII Packet Reference ManualA-12

Página 76

Appendix B. FontsThis appendix contains information you need to work withfonts.Standard Fonts –––––––––––––––––––––––––––––––––––––––––––––The 9490 p

Página 77 - Combining Field Options

Bold FontOCRA-like FontStandard FontReduced FontMPCLII Packet Reference ManualB-2

Página 78 - Restrictions

CG Triumvirate Bold Font CG Triumvirate FontAppendix B. FontsB-3

Página 79

The following table lists the non-print zones for each printer.Printer Top Bottom Left Right9490/9494 .04 inches1.01 mm7.7 dots.16 - .19 inches4.1 - 4

Página 80

Monospaced Font Magnification––––––––––––––––––––––––––––––Decide how wide and tall you want the characters to appearon the labels. The following two

Página 81 - Sub-Fields

Font Magnification1x 2x 3x 4x 5x 6x 7xStandardKLMNOPQ1/100 in. 11.4 22.8 34.2 45.6 57.0 68.4 79.81/10 mm 29.1 58.2 87.3 116.4 145.5 174.6 203.7dots 22

Página 82 - Sample Use for Padding

Proportional Font Magnification –––––––––––––––––––––––––––––Each character in a proportionally spaced font is a differentheight and width. Therefore

Página 83

CG Triumvirate (6 pt.)Width Mag. Minimum Average Maximum1x1/100 in.1/10 mmDots1.042.65263.137.946R6.2515.8812Y2x1/100 in.1/10 mmDots2.085.29476.2515.8

Página 84

Font Magnification1x 2x 3x 4x 5x 6x 7xCG Triumvirate Bold (9 pt.)`abcdef1/100 in. 9.38 18.75 30.21 37.50 46.88 62.50 71.881/10 mm 23.81 47.63 76.73 95

Página 85

The height and width magnification are defined in point size.72 points = one inch. One inch = cell size. The cell size is thebuilt-in space around t

Página 86

Additional Fonts –––––––––––––––––––––––––––––––––––––––––––Optional and downloadable fonts are available for theseprinters. For more information, co

Página 87

Appendix C. Symbol Sets/Code PagesThis appendix contains a listing of the symbol sets and codepages the printer supports. The extended characters ava

Página 88

Selecting a Symbol Set or Code Page ––––––––––––––––––––––––––These printers default to the Internal symbol set. You canselect a different symbol set

Página 89 - Re-Image ON

Internal Symbol Set –––––––––––––––––––––––––––––––––––––––––Code Char. Code Char. Code Char.128 Ç 151 ù 174 «129 ü 152 ÿ 175 »130 é 153 Ö 176n131 â 1

Página 90

Using Supply Layout Grids ––––––––––––––––––––––––––––––––––A supply layout grid contains measurement markers. Thesemarkers help you accurately posit

Página 91 - Sum of Products Calculation

ANSI Symbol Set –––––––––––––––––––––––––––––––––––––––––––To determine the character code, add the column number androw number for the character. Fo

Página 92 - Sum of Digits Calculation

Bold Character Set ––––––––––––––––––––––––––––––––––––––––––These are the printable characters using the Bold font.Code Char. Code Char. Code Char.33

Página 93

OCRA Character Set ––––––––––––––––––––––––––––––––––––––––These are the printable characters using the OCRA font.Code Char. Code Char. Code Char.34 &

Página 94

Code Page 437 ––––––––––––––––––––––––––––––––––––––––––––––Appendix C. Symbol Sets/Code PagesC-7

Página 95 - Chapter 6. Printing

Code Page 850 ––––––––––––––––––––––––––––––––––––––––––––––MPCLII Packet Reference ManualC-8

Página 96 - COPY LABEL1.BCH COM1

ASCII to Hexadecimal Conversion Chart–––––––––––––––––––––––Use the chart below to translate the characters printed on yourtest label. The chart list

Página 97 - Chapter 6. Printing

ASCII to Hexadecimal Conversion Chart (continued)Char. Hex Decimal Char. Hex Decimal$2436 ;3B59%2537<3C60&2638=3D61’2739>3E62( 28 40 ? 3F 63

Página 98

ASCII to Hexadecimal Conversion Chart (continued)Char. Hex Decimal Char. Hex DecimalR5282 i 69105S 53 83 j 6A 106T 54 84 k 6B 107U 55 85 l 6C 108V 56

Página 99

MPCLII Packet Reference ManualC-12

Página 100 - Sequential Method

Appendix D. Format Design ToolsUse copies of these worksheets and grids to create formats,batch data, and check digit schemes. You may want to keepco

Página 101 - Batch Quantity Zero Method

Field Type Description ExamplesText Contains letters, numbers, orsymbols you want to print.item number, item description,department number, price, dat

Página 102 - Optiona l Entry Met hod

Online Configuration Worksheet –––––––––––––––––––––––––––––HEADERBAUDWORD LENGTHSTOP BITSPARITYFLOW CONTROLFCOMMUNICATIONSETUPHEADERIONLINEHEADER

Página 103 - Inquiry Response

Batch Worksheet ––––––––––––––––––––––––––––––––––––––––––––FIELD #DATABATCH DATAEE1E2E3E5HEADERE6E7E400FEED-MODEBATCH-SEPPRINT-MULTMULTI-PARTCUT-TYPE

Página 104

Check Digit Worksheet ––––––––––––––––––––––––––––––––––––––A1 HEADERA2 SELECTOR #A3 ACTIONA4 DEVICEA5 MODULUSA6 LENGTHA7 ALGORITHMWEIGHTSA8ARA

Página 105 - Chapter 7. Status Polling

Supply Layout(Inches)8.07.57.06.56.05.55.04.54.03.53.02.52.01.51.00.50.00.00.51.01.5 2.02.53.03.54.04.2

Página 106

Supply Layout(Metric)01020 304050607080901001072001901801701601501401301201101009080706050403020100203

Página 107

Supply Layout(Dots)0.00.096192288384480 57667276880648038428819296576672768864960105611521536144013441248

Página 108

DDDDRRRR1111RRRR4444NON -PRINTABLETEXT FIELDSD1 HEADERD2 FIELD #FORMATWORKSHEETTCMPCL2FW 10/94D3 # OF CHAR. CCCCCCCC1 HEADERC2 ROWC3 COLUMNC4 G

Página 109

DDDDRRRR1111RRRR4444NON -PRINTABLETEXT FIELDSD1 HEADERD2 FIELD #FORMATWORKSHEETTCMPCL2FW 10/94D3 # OF CHAR. CCCCCCCC1 HEADERC2 ROWC3 COLUMNC4 G

Página 110 - Job Response

Appendix E. Addressing a 9490 PrinterThis appendix describes how to print supplies from a 9490printer used with the Monarch® 9476 Mobile Printing Sta

Página 111

F7. pr_address Printer’s address. Can be any six-byte string in the 0 to255 decimal range enclosed by quotes. We recommendsetting the printer’s addr

Página 112

Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Monarch reserves the right to make

Página 113

Choosing the appropriate font appearance is up to the user.See Appendix B, "Fonts," for samples of each font. Choosingthe appropriate font

Página 114

Step 2. Select a PrinterSelect a specific printer by sending this immediate command:^ADxxxxxx, where ^ is the defined immediate commandcharacter, and

Página 115

C7. bat_voltage Selects the battery voltage. Options:0 15-volt battery1 12-volt batterynThe printer’s LED does not flash after receiving this packet.

Página 116

Returning to Addressed ModeTo change the printer from non-addressed mode to addressedmode:1. Define the printer’s address by sending the communication

Página 117 - Chapter 8. Diagnostics

Troubleshooting ––––––––––––––––––––––––––––––––––––––––––––If you have a problem with the printer that you cannot correct,call Service. See your pri

Página 118 - Using a 9446 or 1460 printer

GlossaryBatch Data2,"Monarch" p Defines the actual information (as fieldswithin { }) printed on the label.Batch ControlE,0,1,4,2 p Defines t

Página 119 - Chapter 8. Diagnostics

Format Header First line of a format, immediatelyfollowing the start of packet ({). A formatheader must begin with F.{F,1,A,R,E,600,400,"Fmt-1&q

Página 120

IndexA –––––––––––––––––––––––––––––adding custom fonts 3-26addressing9490 printer E-1, E-3, E-5algorithm,in sum of digits 5-16algorithm,i

Página 121 - Resetting Printers

charactersfixed using option 1 5-3number of in bar code 4-7number of in non-printable field 4-14number of in text 4-2padding 5-6pl

Página 122 - Calling Technical Support

D –––––––––––––––––––––––––––––daily checklist 1-5datacopy option 4 5-4fixed option 1 5-3for batch 6-5padding option 30 5-6setting

Página 123 - Chapter 9. Errors

errors 7-13about 9-1communication 9-11 - 9-13data 9-1 - 9-10data format failure 9-15display 9-23 - 9-24machine faults 9-16

Página 124

Chapter 3. Configuring the PrinterThis chapter discusses how to✦set communication parameters.✦configure the printer using online configuration packets

Página 125 - Chapter 9. Errors

G –––––––––––––––––––––––––––––generating check digits with option 315-7graphic packetsclearing from memory 3-25gridoverview 2-4H ––––––––––––

Página 126

measurementon a grid 2-4memoryallocating 3-15clearing packets 3-25packet syntax 3-15memory bufferdownloadable fonts 3-19format

Página 127

packet Fsyntax 3-13packet Msyntax 3-15packetsbatch 6-2check digit scheme 5-14clearing from memory 3-25configuration 3-5configu

Página 128

R –––––––––––––––––––––––––––––receive buffer 3-18reimaging, using option 61 5-13removing9490 printer’s address E-1, E-3, E-5requesting jo

Página 129

number of decimal places 3-10online mode 3-7parity 3-13print contrast 3-9print position 3-9print speed 3-9printhead width

Página 130

thicknessline 4-21trailing spacesfinding 10-6transmit buffer 3-18transparent overlayexplanation 4-5, 4-17U –––––––––––––––––––––––––––

Página 132

Published by the Technical Communications Department.Printed in U.S.A.For supplies, service, or assistance call:TOLL FREE:1-800-543-6650 (In the U.S.

Página 133

Using Autobaudn✦Do Not send any data to the printer before using autobaud.✦Autobaud is only available on the 9494 and 9490 printers.You can use the au

Página 134

Using MPCLII Conventions ––––––––––––––––––––––––––––––––––Here are some guidelines to follow when using MPCLII.MPCLII PunctuationUse the following sy

Página 135

✦The field number (0 to 99) must be unique. Monarchrecommends starting at 1, instead of 0.✦Do not use a field number more than once per format.✦Defin

Página 136

✦Use a tilde (~) followed by a 3-digit ASCII code in aquoted string to send function codes or extendedcharacters or send the 8-bit ASCII code.You can

Página 137

This is the syntax to use when you create online configurationpackets:Syntax{Start of Header I,Configuration Header1 to 7 optional packetsA, parameter

Página 138

Defining the System Setup Packet –––––––––––––––––––––––––––––Use the system setup packet (A) to select the power up mode,display language, print sepa

Página 139

Defining the Supply Setup Packet –––––––––––––––––––––––––––––Use the supply setup packet (B) to select supply type, ribbon,feed mode, supply position

Página 140

Defining the Print Control Packet –––––––––––––––––––––––––––––Use the print control packet (C) to set the contrast, print, andmargin adjustment, prin

Página 141

Table of ContentsChapter 1. Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Audience . . . . . . . . . . . . . . . . .

Página 142

Example {I,C,0,-20,-10,0,768,1 p }Uses the default contrast, moves print .1 inch closer to thebottom of the supply (20/192 inches) and .05 inch to the

Página 143

D4. decimals Number of digits to the right of the decimal. Options:0 No digits1 One digit2 Two digits (default)3 Three digitsThe defaults listed abov

Página 144

E2. "ANSI_cd" ~123 Start of header { (left bracket)~044 Parameter , (comma)separator~034 Quoted strings " (quotes)~124 Field separator

Página 145

Resetting Control CharactersYou can change the characters in the previous example backto their original settings by downloading this packet:{I?E?"

Página 146

F5. parity Parity. Options:0 None (default for all printers)1 ODD parity2 EVEN parityF6. flow_control Flow Control. Options:0 None1 DTR (default for

Página 147

Defining the Memory Configuration Packet–––––––––––––––––––––Use the memory configuration packet (M) to customize thesize of your printer’s buffers, w

Página 148

M4. buffer size Buffer size in 1/10K ranges5 - 40 Tr a n s m i t20 - 320 Receive385 - 2295 Image160 - 2295 Format80 - 2295 Downloadable Fonts0 - 1280

Página 149

✦Buffers must total 256K, or 512K if the Optional RAM ispresent.✦"Optional RAM Buffer Sizes" lists the minimum andmaximum values for each bu

Página 150 - Increasing Throughput

About Memory Buffers ––––––––––––––––––––––––––––––––––––––Transmit Buffer Used to send ENQ, job, and uploadresponses. A minimum of 5 is required.The

Página 151 - Wit h Pa ckets

Use the formula below to calculate therequired image buffer size.19.13K x LengthLength is the length of your label in inches.Example19.13K x 6 = 114.7

Página 152 - With Fields

Defining the Supply Setup Packet . . . . . . . . . . . . . . . . . . . 3-8Defining the Print Control Packet . . . . . . . . . . . . . . . . . . . .

Página 153 - Optimized Format

Scalable (Vector)Fonts BufferUsed to image the scalable fontcharacters. Increasing this buffer sizeallows more characters to be saved incache memory,

Página 154

Buffer Allocation ConsiderationsKeep these items in mind when allocating memory.✦Do Not allocate more memory than what is available.✦Free memory from

Página 155 - Appendix A. Samples

Optional RAM Buffer SizesIf you have purchased the 256K Optional RAM for your printer,the following table lists the minimum and maximum values foreach

Página 156

Sending Immedia te Comma nds Immediate commands consist of a three- or four-charactersequence you can send in a packet or embed in yourapplication. E

Página 157 - Mode 0 (Obsolete) Sample

Command Parameter^ADxxxxxxSelects the 9490 printer whose ASCII address is xxxxxx.^CACancels all the batches in the queue.^CBCancels only the current b

Página 158 - Mode 2 Sample

nTo use the immediate command control character or the statuspolling character within your data, use the tilde sequence.Clearing Packets from Memory –

Página 159 - Mode 3 Sample

Using the Font Packet –––––––––––––––––––––––––––––––––––––––You can use a font packet to add or clear downloaded fontsfrom memory, upload your font b

Página 160

Example {W,0,H,Z p }Selects all fonts and uploads the font size information for anydownloaded fonts.The printer returns the following to the host:{W,0

Página 161 - Appendix A. Samples

Cell Height Vertical number of dots to contain thetallest character.Nominal Width Average width for lower-case letters.Nominal Height Average height f

Página 162

Example {I,0,U,N p }Uploads the printer configuration from nonvolatile RAM andreturns the following to the host.A,0,0,0,0,0 p B,1,1,0,0,0 p C,0,0,0,0,

Página 163

Defining Box Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21Chapter 5. Defining Field Options . . . . . . . . . . . . . . .

Página 164 - Sample Batch Packet

Defaults –––––––––––––––––––––––––––––––––––––––––––––––––––For the System Setup Packet (A), all the printers use thesedefaults:Parameter Default Desc

Página 165

For the 9490 printerParameter Default DescriptionIdentifierBSupply Setup Packetsupply_type0Black Mark stock loadedribbon_on1Ribbon installed (transfer

Página 166

For the 1460 printerParameter Default DescriptionIdentifierBSupply Setup Packetsupply_type1Die Cut stock loadedribbon_on1Ribbon installed (transfer su

Página 167 - Appendix B. Fonts

Chapter 4. Defining FieldsThis chapter provides a reference for defining✦the format header✦text, constant text, and non-printable text fields✦bar code

Página 168 - Reduced Font

9494/9490 ranges:9446/1460 ranges:English100 - 600Metric254 - 1524 Dots192 - 1152English075 - 800Metric191 - 2033Dots144 - 1536NOTE:The ranges above a

Página 169 - Appendix B. Fonts

T5. row For monospaced fonts, distance from bottom of print areato the pivot point. The pivot point varies depending onhow text is justified.For prop

Página 170

T6. column Distance from the left edge of the print area to the pivotpoint is the column location. Ranges:English0 - 399Metric0 - 1015Dots0 - 767T7.

Página 171

T10. wid mag Width magnifier, 1-7 (times) or 4-90 points for the scalablefont. If using the scalable font on the 9490 printer, therange is 4-200 poin

Página 172 - CG Triumvirate Bold (9 pt.)

Field placement in the packet is an importantconsideration when using field color attributes. If a linefield is defined before the overlay (text or c

Página 173 - CG Triumvirate (6 pt.)

T15. sym set Symbol set. Options:0Internal Symbol Set1ANSI Symbol Set437DOS Code Page 437 (Domestic)850DOS Code Page 850 (International)NOTE:The CG T

Página 174

Downloading Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6Sequential Method . . . . . . . . . . . . . . . . . . . . . . . . . 6

Página 175 - 6pt Sample

B4. fix/var Fixed (F) or variable (V) length field. Bar Code Number of Characters Fixed or VariableUPCA12 FUPCA+214 FUPCA+517 FUPCA+Price CD12 FUPCE

Página 176 - Font Number

B5. row Distance from bottom of the print area to the pivot point ofthe field. The pivot point varies, depeding on how thefield is justified. Pivot

Página 177

B6. column Distance to the lower left corner of the field from the leftedge of print area. Ranges:English0 - 399Metric0 - 1015Dots0 - 767NOTE:Allow a

Página 178 - Selecting the ANSI Symbol Set

BarcodeTy p eDensitySelectorDensity(% or cpi)NarrowElement(dots/mils)Narrow toWide RatioDataLengthAppearance CodesAvailableCharSetUPCA280% 2/10.4 N/A

Página 179

NOTE:Values in bold indicate the default.B9. height Bar code height, in 1/100 inches, 1/10 mm, or dots.Minimum values:English20Metric51Dots38NOTE:POST

Página 180

B10. text Appearance of text with bar code. For UPC and EAN onlyuse 0-7. For all others, use 8. Options:0Default1No check digit or number system5Nu

Página 181

When you copy this field into another field, the maximumnumber of characters for the final field is 2710. Allow only asmany characters as you need,

Página 182

Defining Constant Text Fields –––––––––––––––––––––––––––––––––A constant text field is a set of fixed characters that prints onall labels. Define ea

Página 183

C3. column Distance to lower left corner of field, from left edge ofprint area. Ranges:English0 - 399Metric0 - 1015Dots0 - 767C4. gap Number of dots

Página 184

Options for the Scalable Font:AOpaque, Normal, Black, BoldBOpaque, Normal, Black, NormalEOpaque, Italics, Black, BoldFOpaque, Italics, Black, NormalNT

Página 185 - –––––––––––––––––––––––

Chapter 10. Printer Optimization . . . . . . . . . . . . . . . . . . . . . . . 10-1Adjusting the Print Quality. . . . . . . . . . . . . . . . . . .

Página 186

C11. field rot Field rotation. Lower left corner of field is the pivot point.Options:0Top of overlay points to top of supply1Top of overlay points to

Página 187

Line TypesYou can create horizontal and vertical lines. There are twoways to define lines.SegmentsYou choose the starting point and endingpoint.Vecto

Página 188

L4. column Distance from left edge of the print area to line origin.Ranges:English0 - 399Metric0 - 1015Dots0 - 767L5. angle/ end rowIf Using Segme

Página 189

L7. thickness Using the chart below for reference, write the desired linethickness (1 to 99) in box L7. Measured in dots.NOTE:Line thickness fills up

Página 190

Syntax Q,row,column,end row,end col,thickness,"pattern" p Q1. Q Box (Quadrilateral) Field.Q2. row Distance from bottom of print areato lower

Página 191 - CONTINUATION

Q5. end col Distance from left edge of printarea to upper right corner ofbox. Ranges same as column.Q6. thickness Using the chart below for reference

Página 192

MPCLII Packet Reference Manual4-24

Página 193

Chapter 5. Defining Field OptionsThis chapter provides a reference for defining✦field options in formats✦check digit packets.Applying Field Options ––

Página 194 - (Metric)

RestrictionsSome options cannot be used together. For example,incrementing (Option 60) and price field (Option 42) optionscannot be applied to the sa

Página 195

Option 1 (Fixed Data) –––––––––––––––––––––––––––––––––––––––Fixed data is information (a company name or store number)you want to print on all labels

Página 196 - WORKSHEET

Appendix C. Symbol Sets/Code Pages . . . . . . . . . . . . . . . . . . . C-1Supported Symbol Sets and Code Pages . . . . . . . . . . . . . C-1Selec

Página 197

Option 4 (Copy Data) –––––––––––––––––––––––––––––––––––––––You can create a field that uses data from another field. Thisis useful for creating merg

Página 198

Copies data from field #3, starting at the first position andcopying three characters. In the destination field, theinformation is placed in position

Página 199

Option 30 (Padding Data) –––––––––––––––––––––––––––––––––––You can add characters to one side of a field to "pad" the field.Padding allows

Página 200 - Step 2. Select a Printer

Option 31 (Calculate Check Digit) ––––––––––––––––––––––––––––The printer generates a check digit if you apply Option 31 tothe field. You cannot use

Página 201 - 1 12-volt battery

Option 42 (Price Field) ––––––––––––––––––––––––––––––––––––––You can apply options that will insert monetary symbolsautomatically. Do not use this o

Página 202 - Returning to Addressed Mode

Option 50 (Bar Code Density)–––––––––––––––––––––––––––––––––You can apply this option to bar code fields when you want tocreate custom densities. Wh

Página 203 - Problem Action

Option 51 (PDF417 Security/Truncation)–––––––––––––––––––––––You can define a security level and choose whether or not totruncate a PDF417 bar code.

Página 204 - Glossary

Option 52 (PDF417 Width/Length) ––––––––––––––––––––––––––––This option defines the image width or length of a PDF417 barcode. If you define a fixed

Página 205

Option 60 (Incrementing/Decrementing Fields)––––––––––––––––––You may have an application, such as serial numbers, in whichyou need a numeric field to

Página 206 - Index - 1

Option 61 (Reimage Field) –––––––––––––––––––––––––––––––––––This option redraws (reimages) a constant field when you havea constant field next to a

Página 207 - Index - 2

Chapter 1. Getting StartedThis manual provides the necessary information to design,write and print a Monarch® Printer Control Language II(MPCLII) form

Página 208 - Index - 3

Using Check Digits –––––––––––––––––––––––––––––––––––––––––Check digits are typically used to ensure that a text or barcode field scans correctly. I

Página 209 - Index - 4

Example {A,1,A,R,10,5,P,"65432" p }Adds check digit scheme number 1 to the printer’s memory.The modulus is 10, the maximum number of charact

Página 210 - Index - 5

4.Divide the sum of the products by the modulus (10 in thiscase), only to the whole number. The balance is calledthe remainder. 9 10 9890 85.Subtr

Página 211 - Index - 6

3.Next, the digits of the products are added together.Two-digit products are treated as two separate digits.This is the sum of the digits.2 + 0 + 2 +

Página 212 - Index - 7

MPCLII Packet Reference Manual5-18

Página 213 - Index - 8

Chapter 6. PrintingThis chapter describes how to ✦download files to the printer✦define the batch header, batch control, and batch datafiles✦modify for

Página 214 - Index - 9

3. Send the communication settings packet to select theprinter’s communication settings. See "Defining theCommunication Settings Packet" in

Página 215 - Index - 10

A batch header begins the file. It tells which format the batchuses and how many labels to print. To record batch data,make a copy of the worksheet

Página 216

Defining the Batch Control Field––––––––––––––––––––––––––––––The batch header must precede this field. The batch controlfield defines the print job

Página 217 - Printed in U.S.A

Defining Batch Data Fields –––––––––––––––––––––––––––––––––––Batch data fields should be sent in field number order. Usecontinuation fields for larg